Interface Solutions
For interface solutions 4TMC recommend parts which are independent of the operating systems. You need no longer a special software for each purpose, machine or a particular manufacturer's product. Web-based management simply requires a browser and a network connection via Ethernet and TCP/IP.
The Web technology is turning the world of process automation and control upside down. It offers supervision of machinery status and control anywhere within a corporate network or the world wide web.
For this open interface solutions we are distributer of products from Wiesemann & Theis GmbH.
Wiesemann & Theis connects serial, Ethernet, USB, PCI and IO for TCP/IP, Ethernet, RS-232, RS-485, USB, 20mA Glass and plastic fiber optic, http, SNMP, OPC, I/O digital, I/O analog, ISA, PCI.
Data Server
| pure.box | ||
|---|---|---|
![]() |
Linux on the DIN rail... NEW: not as a large construction site, but turnkey ready for your application. Use the pure.box as the medium for your application. The pre-configured Linux system is ready to use for everything required by network and Web-based applications: - Use Web-Servers for your own applications and upload Web and PHP pages into the pure.box - C and C++ programs, PHP and shell scripts can be run either CRON- or event-triggered - 750 MB for your own files - Support for HTTPS encrypting |
Data sheet: 50510 |
| Motherbox | ||
![]() |
NEW: Measurement data concentrator for distributed Web-IOs
incl. open Webserver for individual applications - Central database with measurement values from any number of Web-IOs, with access using standardized interfaces (browsers, ODBC, SOAP) - Run PHP scripts cron- and event-triggered (e.g. for server applications) - 750MB for user files (measurement database, user Web and PHP pages, etc.) |
Data sheet: 50501 |
| FTP Data Station | ||
![]() |
NEW: The FTP Data Station offers the functionality of an FTP and Samba server in a compact package. - 750MB internal memory - Access to USB storage devices possible from the network - Memory access from any FTP clients or via SMB signing - Time synchronization using a time server |
Data sheet: 50540 |
back to top
| Web-IO Digital Logger - via Ethernet-TCP/IP | ||
|---|---|---|
![]() |
NEW: Web-IO 6x Digital Input, 6x Digital Output Logger - The onboard Web server allows you to configure and monitor the Web-IO Logger directly from the browser. - Direct access to the outputs over the Web interface is also possible. - Remote control and monitoring via Intra- and Internet - Record up to 1 mil. events with a time stamp - Standard protocols and interfaces such as OPC, SNMP, SYSLOG and AJAX enable trouble-free integration into existing systems. |
Data sheet: 57650 |
| Web-IO Digital - via Ethernet-TCP/IP | ||
![]() |
Web-IO 2x Digital Input, 2x Digital Output PoE - Server connection directly on the Intranet, via TCP/IP sockets, or using services such as SNMP, e-mail, OPC and Web-Server - Remote control and monitoring via Intra- and Internet |
Data sheet: 57637 |
| NEW: ERP-Gateway 2x Digital Input, 2x Output - ERP/PPS system controls digital relays - simply, using the FTP user name - New: Switching using Wayback with any FTP client - ERP/PPS systems such as SAP, Baan, PSI etc. can in this way, using a simple FTP login, send switching pulses to machines, PLCs or any other desired outputs without actual data transmission. |
Data sheet: 57635 |
|
| Web-IO 12x Digital Input, 6x Relay Output - Potential-free switching over the Intra- and Internet |
Data sheet: 57634 |
|
![]() |
NEW: ERP-Gateway 12x Digital Input, 6x Relay Output - ERP/PPS system controls digital relays - simply, using the FTP user name - New: Switching using Wayback with any FTP client - ERP/PPS systems such as SAP, Baan, PSI etc. can in this way, using a simple FTP login, send switching pulses to machines, PLCs or any other desired outputs without actual data transmission. |
Data sheet: 57636 |
| Web-IO 12x Digital Input, 12x Digital Output - Remote control and monitoring via Intra- and Internet |
Data sheet: 57630 |
|
| Web-IO 12x Digital Input, 12x Digital Output - Remote control and monitoring via Intra- and Internet - with RS-232-Com-server functionality |
Data sheet: 57631 |
|
![]() |
Web-IO 19"OEM 24x Digital Input, 24x Digital Output - for installing in 19" racks - Digital signals directly on the Intranet, with services such as SNMP, e-mail, OPC and Web server. - Operates digital inputs/digital outputs, 24 V DC, via browser or via network |
Data sheet: 57632 |
back to top
Web-IO Analog
| Web-IO Analog-In - over Ethernet-TCP/IP | ||
|---|---|---|
![]() |
Web-IO Analog-In 0..20mA / 0..10V - 1x measuring input for currents from 0-20mA - 1x measuring input for voltages from 0-10V |
Data sheet: 57641 |
| Web-IO Analog-In 2x 0..20mA - 2x measuring inputs for currents from 0-20mA |
Data sheet: 57642 |
|
| Web-IO Analog-In 2x 0..10V - 2x measuring inputs for voltages from 0-10V |
Data sheet: 57643 |
|
| Web-IO Analog-In + AC current converter 0..50A - 2x measuring inputs pre-configured for AC current converter 0..50A |
Data sheet: 57644 |
|
back to top
Web-IO application-ready
Monitor climate| Temperature measurement incl. digital relay output | ||
|---|---|---|
![]() |
NEW: Web-Thermograph Relay - Temperature measurement using Pt100 or Pt1000 sensor - Digital relay output - Power provided using Power over Ethernet |
Data sheet: 57616 |
| Temperature, humidity air pressure measurement | ||
![]() |
Web-Thermo-Hygrobarograph PoE - Temperature, humidity and barometric pressure measurement - Power provided using Power over Ethernet |
Data sheet: 57613 |
| Temperature measurement, single-channel | ||
![]() |
Web-Thermograph NTC PoE - Temperature measurement using NTC sensor - Power provided using Power over Ethernet |
Data sheet: 57614 |
| Web-Thermograph Pt100/Pt1000 - Temperature measurement using Pt100 or Pt1000 sensor |
Data sheet: 57610 |
|
| Web-Thermograph Pt100/Pt1000 PoE - Temperature measurement using Pt100 or Pt1000 sensor - Power provided using Power over Ethernet |
Data sheet: 57615 |
|
| Temperature measurement, multi-channel | ||
![]() |
Web-Thermograph 2x Pt100/Pt1000 - Two independent measuring inputs - Temperature measurement using Pt100 or Pt1000 sensor |
Data sheet: 57607 |
| Web-Thermograph 8x Pt100/Pt1000 - Eight independent measuring inputs - Temperature measurement using Pt100 or Pt1000 sensor |
Data sheet: 57608 |
|
back to top
Web-Alarm: Monitor, trigger alarms and record.
| Monitoring digital signals | ||
|---|---|---|
![]() |
Web-Alarm 6x6 Digital - Monitor digital signals and trigger alarms - IO-Monitor with integrated messaging center, Web-based operating software and data logger - Sending alarms over the network via e-mail, SNMP trap, etc. as well as locally using switching contacts. |
Data sheet: 57651 |
Web-Count : Monitor, trigger alarms and record.
| Count pulses and send reports | ||
|---|---|---|
![]() |
Web-Count 6x Digital - Web-based Pulse count acquisition with reporting, operation from the browser and data logging. - Count pulses from up to six signal sources. Acquire and archive pulse counts. - Send event- or time-triggered reports with information about the current counter states by mail for example. |
Data sheet: 57652 |
IP-Watcher: Detect network components that are no longer accessible.
| Monitor network components | ||
|---|---|---|
![]() |
IP-Watcher 2x2 Digital - Generates an alarm when network components no longer respond. - Devices are watched by means of cyclical pinging or regular opening and closing of a TCP port. - Monitor network components and trigger alarms |
Data sheet: 57654 |
RFID: Radio frequency identification for Admission control, logistics and building control systems.
| RFID-Server | ||
|---|---|---|
![]() |
RFID-Server Compact - Mid Range RFID-Reader / Writer, 13.56 MHz - Internal antenna with automatic antenna tuning |
Data sheet: 95001 |
back to top
TCP/IP Ethernet <> serial interfaces: Com-Server for serial interfaces
| Com-Server Highspeed - Industrial Standard solutions | ||
|---|---|---|
![]() |
Com-Server Highspeed Industry - 1x RS232/RS422/RS485, 10/100BT, 24V |
Data sheet: 58631 |
| Com-Server Highspeed Industry with UL Certification - 1x RS232/RS422/RS485, 10/100BT, 24V |
Data sheet: 58631_UL |
|
| Com-Server Highspeed PoE - 1x RS232/422/485, 10/100BT, Power-over-Ethernet |
Data sheet: 58641 |
|
| Com-Server Highspeed PoE 20mA 1 x 20mA/TTY, 10/100BT, Power-over-Ethernet |
Data sheet: 58642 |
|
![]() |
Com-Server Highspeed Isolated - 3x RS232/RS422/RS485 galvanically isolated, 10/100BT, 24V |
Data sheet: 58633 |
![]() |
Com-Server Highspeed 100BaseFX - 1x RS232/RS422/RS485, 100BaseFX, 24V |
Data sheet: 58651 |
| Com-Server 10BaseT - Low Cost Model | ||
![]() |
Com-Server 10BaseT - 1x RS232, 10BT, 5V plug-in power supply |
Data sheet: 58511 |
| LAN-Modems - Ethernet instead of expensive dial-up | ||
![]() |
LAN modem, industry - 10/100BaseT autosensing /1 x RS232 interface DB9 socket, DCE assignment, 24V |
Data sheet: 58620 |
| Com-Server Special - From OEM to 19" | ||
![]() |
Com-Server Highspeed Office - 4x RS232/RS422/RS485, 10/100BT, integrated power supply |
Data sheet: 58034 |
| Com-Server Highspeed Office - 1x RS232/RS422/RS485, 10/100BT, integrated power supply |
Data sheet: 58031 |
![]() |
Com-Server Display Version, 4 serial ports - 4x RS232 port, Ethernet: BNC = 10 Base2, RJ45 = 10 BaseT, Internal power adapter |
Data sheet: 58004 |
| Com-Server Display Version, 1 serial port - 1x RS232 port, Ethernet: BNC = 10 Base2, RJ45 = 10 BaseT, Internal power adapter |
Data sheet: 58001 |
|
![]() |
Com-Server Highspeed OEM - 1x serial TTL, 10/100BT |
Data sheet: 58431 |
| Com-Server OEM credit card module - 1x serial TTL / RS485, 10BT |
Data sheet: 58412 |
|
| Com-Server OEM - 1x serial TTL, 10BT |
Data sheet: 58411 |
|
![]() |
Com-Server Highspeed Compact - 1x RS232/RS422/RS485, 10/100BT, plug-in power supply |
Data sheet: 58231 |
| Com-Server compact version, 10BT and BNC - 1x RS232 port, Ethernet: BNC = 10 Base2, RJ45 = 10 BaseT, Supplied power adapter |
Data sheet: 58201 |
|
![]() |
Com-Server Highspeed OEM 19" - 1x RS232/RSRS485, 10/100BT |
Data sheet: 58331 |
| Com-Server Highspeed OEM 19" - 4x RS232/RSRS485, 10/100BT |
Data sheet: 58334 |
|
![]() |
Com-Server 19" version, 1 serial port - 1x RS232, Ethernet: BNC = 10 Base2, RJ45 = 10 BaseT |
Data sheet: 58301 |
| Com-Server 19" version, 4 serial ports - 4x RS232, Ethernet: BNC = 10 Base2, RJ45 = 10 BaseT |
Data sheet: 58304 |
|
back to top
Serial interfaces
Interfaces for USB, RS232, RS422, RS485 and 20mA| USB - Industry Devices | ||
|---|---|---|
![]() |
USB-Server Industry 2x USB, 10/100BT, Power-over-Ethernet |
Data sheet: 53641 |
| USB Hub Industry USB Hub with 4 USB ports |
Data sheet: 33601 |
|
| USB <> Serial Interfaces | ||
![]() |
USB <> RS232 interface cable 2 Cable version with USB supply |
Data sheet: 38011 |
| USB <> RS232/RS422/RS485 Industry 1kV isolation with overvoltage protection and USB power supply |
Data sheet: 38211 |
|
| USB <> 20mA Industry, Bus Powered 1kV isolation with overvoltage protection and USB power supply |
Data sheet: 34211 |
|
| Serial <> Serial Interfaces | ||
![]() |
RS232 <> RS422/RS485 Compact Converter in dongle housing |
Data sheet: 86000 |
| RS232 <> RS422/RS485 Industry Converter in DIN rail mount housing with 1kV isolation |
Data sheet: 86201 |
|
| RS232 <> RS422/RS485 Industry Built-in overvoltage protection and 1kV isolation |
Data sheet: 86203 |
|
| RS232 <> 20mA Compact Converter in dongle housing |
Data sheet: 84001 |
|
| RS232 <> 20mA Industry Converter in DIN rail mount housing with 1kV isolation |
Data sheet: 84201 |
|
| RS232 <> 20mA S5 Interface Cable Cable version with 4kV isolation |
Data sheet: 84004 |
|
| RS422/RS485 <> 20mA Industry in DIN rail mount with 1kV isolation |
Data sheet: 64201 |
|
| Serial Buffers and T-Switches | ||
![]() |
RS232 Battery Buffer, 4MB Transporting data with the battery-backed buffer |
Data sheet: 88241 |
| RS232 Universal Serial Buffer, 4 MB Storing of serial data and baud rate converter |
Data sheet: 88642 |
|
| RS232 T-Box Tee between 3 RS232 devices |
Data sheet: 85210 |
|
| RS232 Multi Computer Adapter Bi-directional connections between 1 Master / 2 Slaves |
Data sheet: 85603 |
|
| RS232 Universal Serial T-Switch, 4 MB Tee between 3 RS232 devices with memory |
Data sheet: 85643 |
|
back to top
Fiber optics, isolators and line drivers
| Plastic optical fiber cable interfaces | ||
|---|---|---|
![]() |
Interface Fiber optic <> RS232 with 9-pin SUB-D-female Configuration compatible with 9-pin PC interfaces |
Data sheet: 81009 |
| Interface Fiber optic <> RS232 with 9-pin SUB-D-female, Low-Power Power-saving version for short distances |
Data sheet: 81029 |
|
| Interface Fiber optic <> RS232 with 25-pin SUB-D-female Pinout compatible with 25-pin DTE interfaces |
Data sheet: 81025 |
|
| Interface Fiber optic <> RS232 with 25-pin SUB-D-male Pinout compatible with 25-pin DCE interfaces |
Data sheet: 81026 |
|
| Interface Fiber optic <> RS232 in DIN rail mount housing Converter in DIN rail mount housing with 24V-supply |
Data sheet: 81201 |
|
| Interface Fiber optic <> 20mA Converter in DIN rail mount housing with 24V-supply |
Data sheet: 41201 |
|
| Interface Fiber optic <> RS422/RS485 Converter in DIN rail mount housing with 24V-supply |
Data sheet: 61201 |
|
| Fiber optic Repeater Extend fiber optic connections beyond 100 meters |
Data sheet: 11201 |
|
| Serial interfaces with multimode glass fiber optic interface | ||
![]() |
Interface glass fiber optic <> RS232 Send RxD and TxD over glass fiber optic cable |
Data sheet: 81210 |
| Interface glass fiber optic <> RS232 with handshake Send RxD, TxD, RTS and CTS over glass fiber optic cable |
Data sheet: 81211 |
|
| Interface glass fiber optic cable <> RS422/RS485 Connect RS422 or RS485 devices using glass fiber optic cable |
Data sheet: 61210 |
|
| Interface glass fiber optic cable <> Profibus Profibus connections with baud rates of up to 1.5 Mbaud |
Data sheet: 61211 |
|
| Interface glass fiber optic cable <> 20 mA Connect 20mA devices over long distances |
Data sheet: 41210 |
|
| Interface glass fiber optic cable bus <> RS485 Connect RS485 devices over an optical bus |
Data sheet: 65210 |
|
| Interface glass fiber optic cable bus <> Profibus Connect devices with Profibus pinout over an optical bus |
Data sheet: 65211 |
|
| Digital I/O interfaces with glass fiber interface | ||
![]() |
Fiber optics Digital-IO Extender Set 2x2 Remote switching over up to 3.8 km of glass fiber optic cable 2 inputs / 2 outputs |
Data sheet: 17633 |
| Fiber optics Digital-IO Extender Set 8x8 Remote switching over up to 3.8 km of glass fiber optic cable 8 inputs / 8 outputs, with monitoring of the fiber optic connection |
Data sheet: 17634 |
|
| Serial Isolators | ||
![]() |
RS232 Isolator, 1kV isolation voltage Passive isolation for RS232 data lines |
Data sheet: 88001 |
| RS232 Isolator, 4kV isolation voltage Passive isolation for RS232 data and handshake lines |
Data sheet: 88004 |
|
| RS232 Isolator, 50kV isolation voltage Passive isolation with extremely high isolation voltage |
Data sheet: 88050 |
|
| RS232 Isolator, 1kV isolation voltage Active isolation with support for all RS232 signals |
Data sheet: 88205 |
|
| RS422/RS485 Isolator, 1kV isolation voltage Standard version in DIN rail mount housing |
Data sheet: 66201 |
|
| RS422/RS485 Isolator, 1kV isolation voltage with OVP Isolator with integrated overvoltage protection |
Data sheet: 66203 |
|
| Line drivers | ||
![]() |
RS232 line driver set Use RS232 over very long distances - safely and reliably -Serial connection over up to 1000 m -Transmission speed up to 115,200 baud |
Data sheet: 80201 |
back to top